Author: Senthil Kumar, Technical Director | Updated: October 2026

Every power plant is, at heart, a heat management problem. Steam has to be condensed, feedwater heated, oil and generators cooled and waste heat recovered, and each stream brings its own pressure, temperature and water-quality limits. United Heat Exchangers (UHE) is a Coimbatore manufacturer that has been fabricating industrial heat transfer equipment since 1989. This page walks through the condensers, heaters, coolers, vessels and alloys we supply for thermal power, cogeneration and captive power plants.

28Power equipment types and alloy lines described here
ASME VIIIDesign code followed for pressure-containing items
6Alloy families mapped to power plant duty
1989Year we began building heat exchangers

Steam cycle: condensing and feedwater equipment

The condensing and feedwater side of the Rankine cycle, where exhaust steam becomes water again and returns to the boiler.

Surface Condenser / Steam Condenser / Dump Condenser

Steam cycle: condensing and feedwater equipment
Surface Condenser / Steam Condenser / Dump Condenser

Condenses turbine exhaust steam under vacuum so it can return to the boiler circuit; dump condensers absorb surplus steam safely when a turbine trips or bypasses.

  • Used for: steam turbine exhaust, turbine bypass, condensate recovery

Feed Water Heater (HP / LP)

Steam cycle: condensing and feedwater equipment
manufacturer-shell-tube-HEX

Preheats boiler feedwater with extraction steam, raising cycle efficiency and reducing the fuel needed per unit of power.

  • Used for: regenerative feedwater heating in steam power plants

Deaerator

Steam cycle: condensing and feedwater equipment
image-deaerator

Removes dissolved oxygen and gases from feedwater, protecting boiler tubes and piping from corrosion.

  • Used for: boiler feedwater conditioning

Flash Tank

Steam cycle: condensing and feedwater equipment
Flash Tank

Lets high-pressure condensate or blowdown expand so flash steam can be recovered at a lower pressure.

  • Used for: condensate recovery, blowdown heat recovery, drain flashing

Shell and Tube Heat Exchanger

Steam cycle: condensing and feedwater equipment
Shell and Tube Heat Exchanger

The general-purpose unit for auxiliary heating and cooling duties across the steam and water circuits.

  • Used for: process and auxiliary heating or cooling, closed cooling water loops

U Tube Heat Exchanger / U Tube Bundle

Steam cycle: condensing and feedwater equipment
U Tube Heat Exchanger / U Tube Bundle

Each tube is bent into a U fixed at one tubesheet, so the bundle expands freely under thermal cycling, which suits steam and high-pressure duty.

  • Used for: high-pressure and steam applications, frequent thermal cycling

Turbine, generator and auxiliary cooling

Keeping bearings, lubricating oil, transformers and compressed gas inside safe temperature limits.

Air Cooled Heat Exchanger / Air Fin Cooler / Fin Fan Cooler

Turbine, generator and auxiliary cooling
Air Cooled Heat Exchanger / Air Fin Cooler / Fin Fan Cooler

Fans push ambient air over finned tubes, so heat leaves the plant without cooling water, a real advantage at dry or water-restricted sites.

  • Used for: dry cooling of auxiliary circuits, sites with limited water

Lube Oil Cooler / Hydraulic Oil Cooler / Air Blast Oil Cooler

Turbine, generator and auxiliary cooling
Lube Oil Cooler / Hydraulic Oil Cooler / Air Blast Oil Cooler

Hold turbine bearing oil and hydraulic fluid at the right temperature to protect rotating equipment.

  • Used for: turbine lube oil systems, governor and hydraulic oil circuits

Transformer Oil Cooler

Turbine, generator and auxiliary cooling

Carries heat out of transformer insulating oil so generator step-up and station transformers stay within rated temperature rise.

  • Used for: generator and station transformers

Intercooler / After Cooler / Compressor Cooler

Turbine, generator and auxiliary cooling
Intercooler / After Cooler / Compressor Cooler

Remove heat of compression between stages and after the last one, improving compressor efficiency and protecting downstream equipment.

  • Used for: gas turbine fuel gas compressors, plant air compressors

Boiler-side heat recovery

Recovering energy that would otherwise leave through the stack or the blowdown line.

Flue Gas Air Preheater / Air Preheater

Boiler-side heat recovery
Flue Gas Air Preheater / Air Preheater

Moves heat from hot flue gas into incoming combustion air, lifting boiler and heater efficiency.

  • Used for: boilers, fired heaters, biomass and coal-fired units

Heat Recovery Reboiler / Regenerative Heat Exchanger

Boiler-side heat recovery
Heat Recovery Reboiler / Regenerative Heat Exchanger

Reuses heat from hot streams to warm another fluid, lowering fuel consumption and utility demand.

  • Used for: waste heat recovery, cogeneration and captive power

Thermal Oil Heater

Boiler-side heat recovery

Supplies indirect high-temperature heating above 300 °C at low operating pressure, an alternative to high-pressure steam.

  • Used for: thermal oil circuits, solar thermal and biomass heat systems

Floating Head Heat Exchanger

Boiler-side heat recovery
Floating Head Heat Exchanger

A free-moving tubesheet lets the whole bundle be pulled out for cleaning, which helps on services that foul or scale.

  • Used for: fouling services needing regular mechanical cleaning

Pressure vessels and utility air systems

Containment, filtration and instrument air for plant controls and safety systems.

Pressure Vessels (ASME Section VIII)

Pressure vessels and utility air systems
Pressure Vessels (ASME Section VIII)

Code-compliant vessels for holding steam, gas and fluids safely above atmospheric pressure.

  • Used for: steam receivers, gas storage, surge and separation duties

Air Receiver

Pressure vessels and utility air systems
Air Receiver

Stores a reserve of compressed instrument air so control valves and shutdown systems keep responding when demand surges.

  • Used for: control valves and actuators, emergency shutdown systems

Air Dryers

Pressure vessels and utility air systems
Air Dryers

Take moisture out of compressed air, preventing corrosion and freezing and keeping instruments dependable.

  • Used for: dry instrument and service air

Filter Vessels

Pressure vessels and utility air systems
Filter Vessels

Hold the elements that catch particles and entrained water in fuel, lube oil and water circuits.

  • Used for: fuel oil lines, lube systems, water treatment loops

Scrubbing Tower

Pressure vessels and utility air systems
Scrubbing Tower

Removes acid gases, dust and droplets from gas streams before release or further processing.

  • Used for: flue and vent gas cleanup, inlet gas conditioning

Compact and high-performance exchangers

Small, light units for skids, packaged power blocks and advanced cycles.

Plate and Shell Heat Exchanger

Compact and high-performance exchangers
Plate and Shell Heat Exchanger

A welded plate pack inside a pressure shell, combining compact size with high pressure and temperature capability.

  • Used for: compact high-pressure duty, packaged power skids

Compact / Brazed Plate Heat Exchanger

Compact and high-performance exchangers
Compact / Brazed Plate Heat Exchanger

A small, light brazed plate pack that suits closed loops and utility skids.

  • Used for: closed cooling loops, utility skids, heat pump circuits

Printed Circuit Heat Exchanger (PCHE)

Compact and high-performance exchangers
Printed Circuit Heat Exchanger (PCHE)

Diffusion-bonded etched plates pack a large heat transfer area into very little volume at high pressure, which makes them a candidate for supercritical CO₂ power cycles.

  • Used for: high-pressure compact duty, advanced power cycles

Metallurgy mapping for power plant water and steam

Steam, condensate, treated water and seawater each attack metal differently, so the alloy choice largely sets tube life.

Material / Product LinePower Plant Environment & Media Suitability
Carbon Steel Heat ExchangerBoiler feedwater, steam, condensate and general utility water services with low corrosion risk.
Stainless Steel Heat Exchanger (316L / 317L)Demineralised water, condensate polishing and chemically treated cooling water.
Duplex Stainless Steel ExchangerChloride-bearing cooling water, brackish water and coastal plant duty.
Titanium Heat ExchangerRaw seawater cooling and condensers at coastal power stations.
Copper & Brass Heat ExchangersClean cooling water duty, lube oil coolers and closed-loop circuits.
Aluminium Heat ExchangersAir-cooled finned surfaces and clean gas cooling where weight matters.

Application Summary by Power Segment

SegmentTypical UHE equipmentProcess need it serves
Steam power (coal, biomass, cogeneration)Surface and dump condensers, feed water heaters, deaerators, air preheaters, flash tanksExhaust steam condensing, feedwater heating, boiler efficiency, condensate recovery
Gas turbine and combined cycleIntercoolers and aftercoolers, lube oil coolers, air receivers and dryers, filter vesselsFuel gas compression, bearing oil cooling, instrument air and filtration
Captive, waste-heat and renewable powerThermal oil heaters, heat recovery exchangers, fin fan coolers, plate and shell units, PCHEWaste heat recovery, dry cooling, compact skid-mounted duty

Selection Tip: Start with the cooling water quality (treated, brackish or seawater), pick the tube alloy next, then fix the exchanger geometry. Water chemistry, not heat duty, is what usually ends tube life in a power plant.

Get a Free Heat Exchanger Quote

Share your fluids, flow rates, pressures, temperatures and design code with us. Our team will propose the right configuration and material for your power plant application.

Request My Free Quote →

Frequently Asked Questions

Which equipment condenses turbine exhaust steam?

A surface (steam) condenser condenses exhaust steam under vacuum so the water returns to the boiler circuit, and a dump condenser safely absorbs excess steam when a turbine trips or is bypassed.

How can a power plant cool equipment where water is scarce?

Air cooled heat exchangers (fin fan coolers) reject heat to ambient air, so auxiliary cooling needs no water, which suits dry or remote sites.

Which material suits coastal plants using seawater?

Titanium is the standard for raw seawater, and duplex stainless steel is a strong option for brackish or chloride-bearing cooling water.

How is waste heat recovered in a power or cogeneration plant?

Air preheaters capture flue gas heat for combustion air, heat recovery exchangers warm feedwater or process fluids, and thermal oil heaters distribute recovered heat at high temperature without high-pressure steam.

Author: Senthil Kumar, Technical Director — United Heat Exchangers Pvt. Ltd. | Last Updated: October 2026